A. INCINERATOR
Brand, type & model Labco make Controlled air type
Design standard Confirming to MOEF Gazette stds – 1998
CPCB guidelines of 28 March 2016
Type of waste Mixed Biomedical waste
Burning Capacity 10 kg, 20 kg, 30 kg, 50 kg, 100 kg & 200 kg/hr
Auxiliary fuel HSD / LDO
Type of burner operation Automatic
Temperature
Primary chamber 800 Deg C +/- 50 Deg C
Secondary chamber 1050 Deg C +/- 50 Deg C
Residence time of gases in secondary chamber 2 Sec.
B. PRIMARY CHAMBER
Type Cylindrical–vertical with static Solid Hearth
Material & thickness MS Plate 5 mm thick
Refractory thickness 115 mm
Material Refractory Bricks IS - 8
Temperature resistance 14000 C
Insulation thickness 115 mm
Material Insulating Bricks IS - 2042
C. SECONDARY CHAMBER
Type Cylindrical – vertical with static
Solid Hearth Static
Material & thickness MS Plate 5 mm thick
Refractory and insulation Specifications As per Primary Chamber.
D. VENTURI SCRUBBER
Type High energy
MOC SS 316 L
Pressure drop 350 mm WC
Temperature 78 – 800C
Scrubbing media Water with 5% caustic
E. DROPLET SEPARATOR & RECIRCULATION TANK (INTEGRAL)
Type Cyclonic
Temperature 78 - 80 0C
MOC MSRL
Application To separate water droplets from flue gas
Recirculation tank 01 No.
F. I.D. FAN
Type Centrifugal
MOC Mild steel rubber lined casing & SS316 impeller.
G. RECIRCULATION PUMP (1 working + 1 standby)
Type Centrifugal
MOC SS –316
Capacity 6.25 M3/hr
Motor 0.5 HP
H. COMBUSTION AIR FAN
Type Centrifugal
Modulation Manual damper control
I. BURNER
No. of Burners 1 each for primary & secondary chamber
Type Monoblock , Pressure atomized
Fuel Pump 01 No.
Fuel High Speed Diesel
J. CHIMNEY

Minimum stack height will be 30 meters above the ground and will be attached with the necessary monitoring facilities as per requirement of monitoring of ‘general parameters’ as notified under the Environment (Protection) Act, 1986
Self supported / Wire supported Chimney as per the standards:
Material of construction: Mild steel plate lined internally with 3 mm thick Natural hard rubber Suitable for duty condition.
The chimney will be made in 6 pieces having minimum 6 mm thickness. These pieces will be joined at the flanges. The Chimney will be lined internally with 3 mm thick natural hard rubber & painted externally with two coats of heat resistant aluminium paint (2500C). The Chimney will be complete with the following accessories:

The chimney will be connected to the incinerator by an interconnecting mild steel rubber lined duct.

K ELECTRICAL & INSTRUMENTATION

Control Panel will be skid mounted type, PLC based. This will be made in 2 mm CRCA sheet and powder coated in Light Grey shade – 631. Tamper proof PLC will be provided for the control of various parameters and operations.
The field wires used will be heat resistant - special type suitable for duty conditions. These are being used in the Mild steel conduits laid on the hot surfaces like primary-secondary chamber etc.
It will be Power & control circuit of all the motor feeders in a non – compartmentalized panel as the no of feeders is very low. The Panel will be very compact thereby avoiding a separate MCC & Control panel. MMI unit will be provided in the panel for displaying temperature indications and alarms. A printer will be provided for recording parameters e.g. Primary-secondary chamber temperature etc.
Details of Instruments will be provided:

Panel will also have following :

There will be a single line HMI

L. SAFETIES AND CONTROLS

SAFETIES & CONTROLS AS PER CPCB -GUIDELINES OF 2016.